APEX-S Locator

APEX – S is a portable dental Apex Locator, It has the accuracy of 98.33% .With color LED screen, it is more convenient to watch. It can activate more functions of the endo motor when connect our company’s endo motor E – LITE PRO.

Additional information

Brand

Rogin

Charge Power Supply

AC100-240V, 50/60HZ

Color

White

Size

110*67*52mm

Product Details:

 

APEX LOCATOR is usually used before the ENDO MOTOR is used. It is used to measure the length of the root canal to make sure the doctor chooses the right length.

The APEX – S can be used with our company’s endo motor E – LITE PRO. After the connection, it can activate more functions of the endo motor.
Rogin APEX-S:
  • Small and cute in design and portable
  • High accuracy
  • Automatic calibration
  • High resolution and big screen
  • Perfectly combined with EDNO LITE PRO, both length measuring and enlargement
  • Large battery capacity

Product Name: Apex Locator (Models: APEX-S / APEX-D)

Basic UDI-DI(s) :69705149108APAY

EMDN Code:Z121190 – VARIOUS DENTAL STOMATOLOGY INSTRUMENTS

Intended Use:

The Apex Locator is a microprocessor-controlled electronic device used for locating the apex of the root canal and determining the position of the apical foramen (root canal working length) during endodontic treatment, by measuring the ratio of electrical impedance at two frequencies (400 Hz and 8 kHz). The essential performance of the device is the accurate determination of the apical foramen position (measurement accuracy ±0.5 mm); loss or degradation of this performance, for example due to electromagnetic disturbances, may result in an erroneous working length. The device is intended to support, not replace, radiographic examination.

Intended users and Environment of Use

The Apex Locator is to be used only in a clinical or hospital environment (hospitals, dental clinics and dental offices), following good dental practice, by qualified dental professionals such as general practitioners as well as Endo specialists (Endodontists) and Dental Assistants who have been trained in the use of the device. It is not intended for use by laypersons or in a home environment.

Safety Information:

<Warnings>

  • Only dentists and dental professionals trained and qualified in endodontic treatment are allowed to use this device.

  • Do not use this product except for dental service and endodontic treatment. Use it in accordance with the intended use; do not use it for implants or other non-endodontic dental procedures.

  • Before Use: The device is not supplied sterile. The reusable patient-contacting accessories (file clip, lip hook and touch probe) must be cleaned, disinfected and steam-sterilised (134 °C / 5 min, fractionated pre-vacuum, EN ISO 17665) before each use; the main unit, measuring wire and AC adapter must be cleaned and disinfect-wiped. Use original components only.

  • After use: Remove gross soiling with cold water (<40 °C) immediately after use and complete reprocessing within 15 minutes. Do not use a fixating detergent or hot water (>40 °C), as residues may become fixed and the instruments may be very difficult to clean.

  • Do not place the device in humid surroundings or anywhere it can come into contact with any type of liquid. Do not expose it to direct or indirect heat sources, and do not use or store it in the presence of a flammable anaesthetic mixture with air, oxygen or nitrous oxide (degree of protection IPX0).

  • Special precautions for electromagnetic compatibility (EMC) are necessary. Install and operate the device strictly in accordance with the EMC guidelines; do not use it near fluorescent lamps, radio transmitters, remote controls, portable or mobile RF communication equipment, MRI, diathermy or electrocautery equipment, and keep portable RF equipment at least 30 cm from any part of the device. Do not use the device while it is charging.

  • If any irregularity occurs during treatment (damaged cables, electrical parts exposed to water, battery malfunction, use of unsupported devices, erratic readings or device failure), switch the device off immediately and discontinue use. Never open or repair the device yourself; contact the agency or the manufacturer.

  • Always confirm the electronically determined working length with pre- and post-operative radiographs; do not rely on the apex locator alone. Gloves and a rubber dam are compulsory during treatment.

  • Strictly follow this Instruction for Use and the General Processing Instructions For Endodontic Products to minimise the following risks to the device, the patient

and/or the user:

○ Inaccurate working-length determination, leading to over-instrumentation or under-instrumentation of the root canal.

○ Cross-contamination due to inadequate cleaning, disinfection or sterilisation of the reusable accessories.

○ Electric shock or fire resulting from damaged cables, liquid ingress, battery malfunction or the use of unsupported components.

○ Electromagnetic interference causing erratic readings, loss of essential performance or device failure.

○ Breakage, detachment or swallowing/aspiration of small reusable parts (file clip, lip hook, touch probe).

○ Toxic or allergic reactions caused by processing residues.

○ Device damage or measurement failure due to wear, cracks, brittleness or other material degradation of reusable components.

<Contraindications and prohibitions>

The device is not intended for use on patients wearing cardiac pacemakers, implantable cardioverter-defibrillators (ICDs) or other active implantable electrical devices. Safety and effectiveness have not been established in pregnant women and children; pregnant or breastfeeding women should be treated only under the guidance of a physician, weighing the benefits against the risks and avoiding unnecessary procedures.

The following uses are prohibited:

○ Use for implants or any non-endodontic dental procedure; use in humid surroundings, in contact with liquids, near heat sources, or in the presence of a flammable anaesthetic mixture with air, oxygen or nitrous oxide.

○ Use while the device is charging, with non-original accessories or cables, or after any unauthorised opening, modification or repair of the device.

○ Measurement in canals with an enlarged apical foramen, active bleeding or blood overflow beyond the apical foramen, a damaged crown, cracked roots, gutta-percha-filled canals, or a conductive fluid path between the inside and outside of the canal (e.g. metal crowns or bridges causing a short circuit).

<Adverse Reactions>

No device-specific adverse reactions or undesirable side effects have been identified for the Apex Locator. Temporary post-operative discomfort could arise generally as a result of receiving root canal treatment. An incorrect working length may, however, result in over-instrumentation, under-instrumentation or transient periapical irritation; the reading must therefore always be confirmed radiographically. Any serious incident occurring in relation to the device should be reported to the manufacturer and to the competent authority of the Member State in which the user and/or patient is established.

Direction for Use

  1. Charge the device for more than 4 hours before first use with the original AC adapter (input AC 100-240 V, 50/60 Hz; output 5 V / 1 A; a full charge takes approximately 4 hours). Do not use the device while it is charging, and keep the operator more than 2 m away during charging.

  2. Check the battery symbol on the LCD. When the power indicator flashes or the low-battery symbol appears, stop using the device and recharge it. If the device is not used for a long period, keep it fully charged at least once a month.

  3. Before each patient, clean, disinfect and steam-sterilise the reusable patient-contacting accessories (file clip, lip hook, touch probe) and wipe-disinfect the main unit, measuring wire and AC adapter. Verify that all parts are dry, undamaged and legibly marked.

  4. Insert the plug of the measuring wire fully into the socket of the main unit. Measurement cannot be performed unless the plug is completely inserted.

  5. Connect the lip hook and the file clip (or the touch probe) to the two sockets at the other end of the measuring wire. Gently pull the roots of the connecting section to confirm a firm connection; never pull on the wire itself, and keep the endodontic file and file clip away from any other metal or instruments.

  6. Switch the device on (on APEX-S, press the power button for more than 0.8 seconds) and confirm that the measuring interface appears. Perform the self-test by short-circuiting the file clip against the lip hook: on APEX-S the ‘APEX’ sign flashes, ‘-3’ is displayed, the length bar lights up completely and a rapid beep sounds; on APEX-D the display shows ‘- -‘ and ‘OVER’. If the test fails, replace the file clip or the measuring wire; if the fault persists, discontinue use and contact the distributor.

  7. Verify accuracy with the supplied tester (on APEX-S a displayed value of 0.2, 0.3 or 0.4 indicates correct function). It is recommended to repeat this accuracy test every one to two weeks.

  8. Select the desired acoustic volume and, on APEX-S, set the reference point between 0.0 and 0.6 (0-1 mm) using the reference key; the settings are saved automatically.

  9. Isolate the tooth with a rubber dam and wear gloves. Dry the access cavity with a cotton pellet / air blower and remove liquid, tissue debris and old filling material. Moisten very dry canals with saline or hydrogen peroxide and dry the access cavity again. Ensure that the file and file clip do not contact the gingiva, metal crowns/bridges, amalgam or other metal; NaClO concentrations above 3% may reduce accuracy.

  10. Hang the lip hook on the patient’s lip so that it contacts the oral mucosa as the reference electrode. Clip the file clip vertically onto the metal shaft of the endodontic file (a resin needle file is recommended); the touch probe may be used instead of the file clip where access to posterior teeth is difficult.

  11. Advance the file slowly towards the apex while observing the coloured bar and numeric display. Blue bars indicate the region before the apical foramen; green bars indicate the apical zone (0.0-0.6); ‘0.0’ / ’00’ with a continuous beep indicates the major (anatomical) apical foramen; red bars with a flashing ‘APEX’ / ‘OVER’ and a rapid beep indicate that the file tip has passed the apex. The scale indicates a trend only and does not represent an absolute distance in mm.

  12. When ‘0.0’ / ’00’ is reached, adjust the silicone stop on the file to the coronal reference point (incisal edge or fossa edge), withdraw the file and measure the distance between the file tip and the stop: this is the working length. Subtract 0.5-1 mm from the measured length to determine the working length for shaping, in order to avoid over-instrumentation.

  13. Confirm the working length with pre- and post-operative radiographs; do not rely on the apex locator alone. If the bar graph jumps suddenly or immediately displays ‘OVER’, withdraw the file and check for short circuits, excess irrigation solution/saliva/blood, perforation, metal restorations, an obliterated canal or a file that is too small for the canal.

  14. After treatment, switch the device off (it shuts down automatically after 8 minutes without operation), disconnect the accessories and reprocess them immediately: remove gross soiling with cold water (<40 °C), pre-clean manually, then use an automated washer-disinfector (ISO 15883 series; 5 min thermal disinfection at ≥93 °C, A0 >3000), dry, inspect, pack (ISO 11607) and steam-sterilise (134 °C / 5 min, EN ISO 17665). Discard any component showing deformation, cracks, brittleness or illegible markings, and store the sterilised accessories in a dry, clean and dust-free environment.

Manufacturer Information

  • Manufacturer Name: Shenzhen Denco Medical Co., Ltd
  • Manufacturer Address: Room 3108, Block 6, Tian’an Cloud Park, Bantian street, Longgang District, Shenzhen, 518129 Guangdong P.R. China
  • Factory Address: Room 101, 201, 301B, 401&801, Block 5, Renluo 6 Road No. 6, Shuikou Street, Huicheng District, Huizhou, 516000 Guangdong, P.R. China
  • Single Registration Number (SRN) of Manufacturer: CN-MF-000014271

Notified Body Information

  • Notified Body Name: TÜV Rheinland LGA Products GmbH
  • Address: Tillystraße 2, 90431, Nürnberg, Germany
  • Notified Body Number: 0197

Authorised representative (AR) Information

  • Authorised representative Name: Share Info GmbH
  • AR’s Address: Am Schulzentrum 12, 41564 Kaarst, Germany
  • Single Registration Number (SRN) of AR: DE-AR-000005132

This device is supplied with paper instructions for use. Please carefully read the instructions before use.

FAQ

Q: Are you trading company or manufacturer?
A: We are original manufacturer. We can do OEM/ODM business. Our company mainly produces Dental products.

Q: How long is your delivery time?
A: Group buying delivery time: 30-60 days; General delivery time: 20 days.

Q: What is your terms of payment?
A: T/T 30% as deposit, and 70% before delivery.

Q: How can I get your catalogue and price list?
A: Please let us know your email or contact us from website directly for our catalogue and price list.

Q: How much will the shipping charges be?
A: It depends on the size of your shipment and the method of shipping. We will offer the charge to you as you requested.

Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email with the suffix “@rogindental.com”. 

Please leave your contact information so that we can contact you as soon as possible