Touch Screen Endo Motor with Apex Locator.
| Brand | Rogin |
|---|---|
| Charger power supply | AC100-240V |
| Torque range | 0.6N.cm-4.6N.cm |
| Speed range | 150rpm-1000rpm |





Main accessories includes:

Product Name: PAD Endo Motor and Apex locator Unit (Model: E-MATE PAD)
Basic UDI-DI(s) :6942007308EPFZE
EMDN Code:Z121101 – INSTRUMENTS FOR DENTAL TREATMENT UNITS; Z121190 – VARIOUS DENTAL STOMATOLOGY INSTRUMENTS
Intended Use:
The PAD Endo Motor and Apex locator Unit is a cordless endodontic treatment motorised handpiece with integrated root-canal length measurement. It is intended for the preparation and enlargement of root canals with rotary NiTi files and for the electronic measurement of root-canal working length, and can enlarge the canal while monitoring the position of the file tip inside the canal. Length measurement uses multi-frequency impedance-ratio technology: the device determines the position or length of the apical foramen of vital teeth from the change in impedance at two sine-wave frequencies (8 kHz and 400 Hz), as the resistance between the file tip and the oral reference electrode approaches approximately 6.5 kΩ at the apical constriction. Six integrated functions are provided: apex location, reciprocating rotary motion, automatic deceleration in the apical zone, automatic reversal in the apical zone, automatic torque reversal, and simultaneous measurement and enlargement.
Intended users and Environment of Use
The PAD Endo Motor and Apex locator Unit is to be used only in hospitals, clinics or dental offices, following good dental practice, by legally qualified dental professionals who are experienced in the operation of endodontic devices and understand the English language; no special training is required except where the legal regulations of the country concerned provide otherwise. It is not intended for use by laypersons or in a home environment.
Safety Information:
<Warnings>
This device must be operated by professional and qualified dentists. Please read this Instruction Manual carefully before first operation. Any serious incident occurring in relation to the device should be reported to the manufacturer and to the competent authority of the Member State in which the user and/or patient is established.
Use the device only for dental service and endodontic treatment, in accordance with the intended use. Do not make any unauthorised change or modification to the device. Use only original contra-angles, measuring wires, file clips, lip hooks, touch probes, adapters, cables and lithium batteries supplied or specified by the manufacturer; non-specified accessories may cause measurement errors, device malfunction or safety hazards.
Before Use: The device is not supplied sterile. Group A components (contra-angle, lip hook, file clip and touch probe) must be cleaned, disinfected and steam-sterilised before each use; Group B components (motor handpiece, AC adapter and handpiece base) may only be wipe-disinfected and must never be autoclaved or subjected to automated cleaning. Group A components are validated for a maximum of 250 complete reprocessing cycles and must not be reused beyond that limit or if cracks, corrosion, brittleness or mechanical malfunction are present.
After use: Remove gross soiling with cold water (<40 °C) immediately after use and complete reprocessing within 15 minutes. Do not use a fixating detergent or hot water (>40 °C), as residues may become fixed and the instruments may be very difficult to clean. Keep the contra-angle clean and free from contamination, as the internal parts may be damaged if contaminated.
Do not directly or indirectly place the device near heat sources, and do not use or store it in the presence of a flammable anaesthetic mixture with air, oxygen or nitrous oxide or in an oxygen-enriched environment. The device is ordinary equipment (IPX0) and must be protected against liquid ingress and impact (in particular, do not drop it). Prolonged use of the Reciprocating Motion Mode may cause the motor handpiece to overheat; allow it to cool before further use.
Special precautions for electromagnetic compatibility (EMC) are necessary. Install and operate the device strictly in accordance with the EMC information; do not use it near active HF surgical equipment, the RF-shielded room of an MRI system, fluorescent lamps, radio transmitters, remote controls or portable/mobile RF communication equipment, and keep portable RF equipment at least 30 cm from any part of the device including its cables. Do not use the device while it is charging, and use only the manufacturer-approved power adapter and battery.
The following patient-related factors may influence reading accuracy: blocked, cracked or perforated root canals, root fracture or perforation, metal crowns or bridges contacting the file or lip hook, a conductive fluid path linking the inside and outside of the canal, very dry root canals, and the file or file clip contacting other metal or instruments. Ensure the access cavity is free of liquid and residual pulp and isolate the tooth with a rubber dam.
The scale indication on the screen does not represent a distinct length or distance in mm; it indicates only the progression of the file towards the apex. The apical position corresponds to an indicated ‘0.0’; subtract 0.5-1.0 mm from it to determine the working length for shaping. Do not use a broken, bent or non-ISO-conforming file, and set torque and speed in accordance with the file manufacturer’s recommended specifications (ISO 3630-1 / ISO 1797:2017).
Carry out a pre-test before use and pay full attention to the device if it becomes loose, vibrates, is noisy or becomes hot; if any abnormal phenomenon occurs, stop using the device immediately and contact the local distributor or the manufacturer. Do not press the push cover of the contra-angle or remove the contra-angle before rotation has stopped. Never open, service or repair the device yourself, and never clean, service or maintain any part of the equipment while a patient is connected.
Strictly follow this Instruction for Use to minimise the following risks to the device, the patient
and/or the user:
○ Inaccurate working-length determination, leading to over-instrumentation, under-instrumentation or perforation of the root canal.
○ Cross-contamination due to inadequate cleaning, disinfection or sterilisation of Group A components, or reuse beyond the validated 250 reprocessing cycles.
○ Separation (breakage) of the rotary NiTi file or of the contra-angle, and aspiration or swallowing of small detached parts.
○ Electric shock, fire or burns from a damaged cable, liquid ingress, battery malfunction or the use of an unapproved adapter or battery.
○ Electromagnetic interference causing erratic readings, unintended motor reversal, loss of essential performance or device failure.
○ Thermal injury or patient discomfort from an overheated motor handpiece during prolonged reciprocating operation.
○ Toxic or allergic reactions caused by processing residues, allergic reactions in patients with known metal allergy, and device damage due to wear, cracks, brittleness or other material degradation of reusable components.
<Contraindications and prohibitions>
The device is not intended for use on patients wearing cardiac pacemakers, implantable cardioverter-defibrillators (ICDs) or other active implantable electrical devices,The following uses are prohibited:
○ Use with non-original or unspecified accessories, contra-angles, measuring wires, adapters, cables or lithium batteries; any unauthorised modification, opening or repair; use while charging; and use of a double-head measuring wire in the combined enlargement-with-apex-locator mode.
○ Use in the presence of a flammable anaesthetic mixture with air, oxygen or nitrous oxide or in an oxygen-enriched environment; in humid surroundings or in contact with liquids; near heat sources; and in the vicinity of active HF surgical equipment or magnetic resonance imaging systems.
○ Length measurement in blocked, cracked or perforated canals, in teeth with a root fracture or perforation, where metal crowns or bridges contact the file or lip hook, where a conductive fluid path links the inside and outside of the canal, or in very dry canals; and any reuse of Group A components beyond the validated 250 reprocessing cycles.
<Adverse Reactions>
No device-specific adverse reactions or undesirable side effects are identified in the Technical Documentation Temporary post-operative discomfort could arise generally as a result of receiving root canal treatment. Any serious incident that has occurred in relation to the device should be reported to the manufacturer and to the competent authority of the Member State in which the user and/or the patient is established.
Direction for Use
Charge the device for more than 4 hours before first use with the original AC adapter (input AC 100-240 V, 50/60 Hz, 1.0 A; output DC 10 V / 1.5 A). Connect the adapter to the right-side socket of the main unit; the green charging indicator extinguishes when charging is complete (approximately 4 hours). Do not use the device while charging.
When the power indicator flashes or the battery level is low, stop using the device and recharge it. Use only the original adapter and battery; only a trained technician or the distributor may replace the battery. Remove the battery if the handpiece will not be used for an extended period, and dispose of waste batteries in accordance with local regulations.
Before each patient, verify that Group A components (contra-angle, lip hook, file clip, touch probe) have not exceeded 250 reprocessing cycles and show no cracks, corrosion, discoloration, brittleness or mechanical malfunction; then clean, disinfect and steam-sterilise them. Wipe-disinfect Group B components (motor handpiece, AC adapter, handpiece base) and never autoclave or immerse them. Clean all parts that may contact the patient.
Assemble the device: align the locating points of the contra-angle and the motor handpiece so that they connect smoothly; insert the plug of the measuring wire into the left-side measuring port of the main unit; connect the file clip and the lip hook (or touch probe) to the two sockets of the measuring wire. Use the single-head measuring wire for the combined enlargement-with-apex-locator mode.
Press the ON/OFF button to power on and tap ‘Apex’ on the touch screen to enter root-canal length-measurement mode. The unit shuts down automatically after 3 minutes without operation in this mode (5 minutes in rotary mode). Adjust screen brightness and beep volume from the Home menu as required.
Perform the apex-locator calibration/self-test: with the accessories correctly connected, touch the file clip to the lip hook; a red screen displaying ‘-0.1’ confirms normal function. If there is no display, the file clip or measuring wire is damaged and must be replaced. Run ‘Calibration’ from the Home menu whenever the contra-angle is changed.
Select a user-defined ‘Program’ (up to 9 programmes) or a built-in file system, and set speed (150-1000 rpm) and torque (0.6-4.6 N·cm) in accordance with the file manufacturer’s recommendations. Use CE-marked rotary files conforming to ISO 3630-1 / ISO 1797-1:2017; files are not supplied with the device and must be purchased separately.
Select one of the four working modes (continuous rotation, reverse rotation, reciprocating motion with adjustable angles 30°-370°, or automatic torque control) and set the automatic-reverse position in the apical zone. When the ‘Apex’ icon is enabled, measurement and enlargement run simultaneously: the motor decelerates automatically near the apex, the beep accelerates, and the motor reverses at the preset position.
Isolate the tooth with a rubber dam and wear gloves. Dry the access cavity and remove liquid, residual pulp tissue and old filling material; moisten very dry canals with saline and dry the access cavity again. Ensure that the file and file clip do not contact the gingiva, metal crowns or bridges, amalgam or other metal.
Hang the lip hook on the patient’s lip so that it contacts the oral mucosa as the reference electrode (moisten the mucosa if dry). Attach the file clip vertically to the metal part near the file shank; use the touch probe instead of the file clip where access to posterior teeth is difficult.
Advance the file slowly towards the apex while observing the touch LED display: blue bars indicate the region before the apical foramen, green bars indicate that the file is near the apical foramen, and red bars with negative values, a flashing ‘APEX’ and a rapid alarm indicate that the file has passed beyond the foramen. A continuous alarm sounds when the file is less than 2 mm from the apex. The numeric scale is a trend indicator only and does not represent a distance in mm.
When the screen indicates ‘0.0’ (the apical position), adjust the silicone stop on the file to the coronal reference point (incisal edge or fossa edge), withdraw the file and measure the distance between the stop and the file tip to obtain the working length. Subtract 0.5-1.0 mm from the indicated position when determining the working length for shaping, and confirm the result with pre- and post-operative radiographs.
If readings are unstable or inaccurate, or the file does not work in the combined mode, check for a blocked/perforated or very dry canal, excess liquid or residual pulp, dry oral mucosa, a poor file-clip or measuring-wire connection, a double-head measuring wire, metal restorations and nearby sources of electromagnetic interference. Consult the Troubleshooting table; if the problem cannot be resolved, contact the local distributor or the manufacturer.
After treatment, switch the device off, disconnect the patient and the accessories, and reprocess immediately: remove gross soiling with cold water (<40 °C), pre-clean manually, then use an automated washer-disinfector (ISO 15883 series; 5 min thermal disinfection at ≥93 °C, A0 >3000), dry, inspect, pack (ISO 11607) and steam-sterilise Group A components ( 134 °C / 5 min ,EN ISO 17665), with 16-40 min drying and at least 30 min cooling. Log each cycle and discard components at or beyond 250 cycles. Wipe-disinfect Group B components. Dispose of the lithium battery and electrical/electronic components in accordance with WEEE 2012/19/EU and local regulations.
Authorised representative (AR) Information
This device is supplied with paper instructions for use. Please carefully read the instructions before use.
Q: Are you trading company or manufacturer?
A: We are original manufacturer. We can do OEM/ODM business. Our company mainly produces Dental products.
Q: How long is your delivery time?
A: Group buying delivery time: 30-60 days; General delivery time: 20 days.
Q: What is your terms of payment?
A: T/T 30% as deposit, and 70% before delivery.
Q: How can I get your catalogue and price list?
A: Please let us know your email or contact us from website directly for our catalogue and price list.
Q: How much will the shipping charges be?
A: It depends on the size of your shipment and the method of shipping. We will offer the charge to you as you requested.
We will contact you within 1 working day, please pay attention to the email with the suffix “@rogindental.com”.